Sunny Central 100 Outdoor / 100 Indoor

Search green products
Search green companies
Sunny Central 100 Outdoor / 100 Indoor
Central Inverters
SUNNY CENTRAL- High Tech for solar power stations
We have developed the Sunny Centrals specially for use in large PV power stations and open-field plants. Hence they possess completely special properties. String monitoring, capacity for teamwork and the ability to feed into the medium-voltage power grid make them first choice for PV systems with homogenous structure.
Sunny Central 100 Outdoor / 100 Indoor
Concentrated power at an attractive price
Powerful and efficient, the Sunny Central 100 Outdoor is perfectly suited for implementing large-scale PV plants in open spaces. With a weatherproof enclosure and extended temperature range, it is the first choice for reliable outdoor operation, even under extreme ambient conditions. Operators of large PV power stations benefit twice. The compact design greatly reduces installation work and thanks to innovative transformer technology, the inverter’s peak efficiency has again been improved making it the most efficient central inverter of its class. The indoor version is equipped with a special ventilation concept for use inside buildings.
|
Flexible
|
Reliable
|
|
|
Optional
|
|
Sunny Central 100 Outdoor / Indoor |
Sunny Central 100 Outdoor / Indoor HE |
|
| Input (DC) | ||
| Max. DC power (@ cos φ=1) | 105 kW | 105 kW |
| Max. input voltage | 1000 V | 1000 V |
| MPP voltage range (@ 25 °C) | 450 V – 820 V 1) | 450 V – 820 V 1) |
| Rated input voltage | 500 V | 500 V |
| Maximum input current | 235 A | 235 A |
| Number of independent MPP inputs | 1 | 1 |
| Number of DC inputs | 3 | 3 |
| Output (AC) | ||
| Rated power (@ 25 °C) | 100 kVA | 100 kVA |
| Nominal AC voltage / range | 400 V / 360 V – 440 V | 300 V / 270 V – 330 V |
| AC power frequency | 50 Hz, 60 Hz | 50 Hz, 60 Hz |
| Rated power frequency / rated power voltage | 50 Hz / 400 V | 50 Hz / 300 V |
| Max. output current | 145 A | 193 A |
| Max. THD | < 3 % | < 3 % |
| Power factor at rated power | 1 | 1 |
| Feed-in phases / connection phases | 3 / 3 | 3 / 3 |
| Efficiency 2) | ||
| Max. efficiency / European efficiency | 97.6 % / 97 % | 97.6 % / 97 % |
| Protection | ||
| Input side disconnection device | Motor-driven DC circuit breaker | Motor-driven DC switch-disconnector |
| Output side disconnection device | opt. | opt. |
| Grid monitoring | yes | yes |
| Ground fault monitoring | opt. | opt. |
| Insulation monitoring | opt. | opt. |
| Galvanic isolation | yes | yes |
| Surge arrester for auxiliary supply | yes | yes |
| General Data | ||
| Dimensions (W / H / D) |
1835 / 1280 / 830 mm (72.3 / 50.4 / 32.7 inch)) |
1835 / 1280 / 830 mm (72.3 / 50.4 / 32.7 inch)) |
| Weight | 925 kg | 505 kg |
| Operating temperature range | -20 °C ... +50 °C 3) | -20 °C ... +50 °C 3) |
| Max. self-consumption (in operation) / self-consumption (at night) | 1000 W / < 50 W | 1000 W / < 50 W |
| External auxiliary supply voltage | 230 V, 50 / 60 Hz | 230 V, 50 / 60 Hz |
| Cooling concept | Forced cooling | Forced cooling |
| Degree of protection: electronics / connection area (as per IEC 60529) | Outdoor IP54, IP44 / IP54, IP44 | IP54, IP44 / IP54, IP44 |
| Application | Unprotected outdoors | Unprotected outdoors |
| Maximum permissible value for relative humidity (non-condensing) | 15 % ... 95 % | 15 % ... 95 % |
| Maximum operating altitude above MSL | 1000 m | 1000 m |
| Fresh air consumption | 2300 m³/h | 2300 m³/h |
| Features | ||
| DC terminal / AC terminal | Ring terminal lug / ring terminal lug | Ring terminal lug / ring terminal lug |
| Display | LC text display | LC text display |
| Communication protocols / Sunny String-Monitor | Ethernet / RS485 | Ethernet / RS485 |
| Analog inputs / overvoltage protection for analog inputs | Optional 1 x PT 100, 2 x Ain 4) / opt. | Optional 1 x PT 100, 2 x Ain 4) / opt. |
| Certificates and approvals (more upon request) | EN 61000-6-2, EN 61000-6-4, CE conformity, R.D. 1663 / 2000 | EN 61000-6-2, EN 61000-6-4, CE conformity, R.D. 1663 / 2000 |
| Type designation | SC 100 Outdoor | SC 100 Indoor/OutdoorHE |
|
1) At 1.05 VAC, nom and cos φ = 1 2) Efficiency measured without an internal power supply 3) Compliance with nominal values up to an ambient temperature of +40 °C, at an ambient temperature of +50 °C compliance with nominal values for 2 hours. 4) Terminal for an analog sensor provided by the customer in two-wire and four-wire version |
Additional Information
- manufacturer: SMA Solar Technology / Germany /